• Home
  • About Us
    • About Us
    • History
    • Global Projects
    • News
  • TELIDE Products
    • Air Driven,Gas Booster Power Units
    • Valve Test Benches
    • Valve Grinders
    • Hydrostatic & Impulse Test Benches
    • Diaphragm Compressor HP System
    • Bolt Tensioner & Hydraulic Wrench Pumps
    • Computer Registration System
    • Non-standard Components Customization
  • Agent Products
    • Sprague Products Air Driven Pump
    • American HiP High Pressure Components
    • Nova Swiss High Pressure Components
    • Denmark ScanWill Hydraulic Intensifiers
    • Swiss NOZAG Screw Jacks
  • Applications
    • General Industry
    • Auto Industry
    • Hydrogen
    • Oil & Gas
    • Nuclear Power
    • Research and University
    • Aviation Industry
    • Special Equipment Inspection
    • Cables
    • Petrochemical & Chemical
  • Test Service
    • Valve Testing and Maintenance
    • Hydrostatic & Impulse Test for Pipes, Valves, Fittings
    • HP Hydrogen Components Charging and Testing
    • Design and Manufacture Non-standard Clamping Platform
    • Test Software Customization
    • Test Equipment Rental
  • After Sales
    • Q & A
    • After-sales service
    • Technical Article
    • Download
    • Video
  • Contact Us
CN
  • 끠
  • Q & A
  • After-sales service
  • Technical Article
  • Download
  • Video

Q & A

Q: What are the features of the Telide valve test bench?
ꄶ ꄶ ꄷ

A: Telide excels in high-pressure fluid control and applies its experience to valve test benches.

Q: What are the specific applications of Telide high pressure products in China?
ꄶ ꄶ ꄷ

A: Nitrogen 600 MPa. Hydrogen 300 MPa. Liquid 700 MPa.

Q: What is the reliability of Telide products?
ꄶ ꄶ ꄷ

A: Neither gold nor silver prize is as valuable as the customer's praise. Welcome to research specific users.

Q: What is the technicality of Telide products?
ꄶ ꄶ ꄷ

A: Telide focuses on the high pressure field and has a stable technical team with over 20 years of experience.

Q: What is the cost-effectiveness of Telide products?
ꄶ ꄶ ꄷ

A: What our customers say: Rest assured at critical moments.

Telide products can help customers quickly recoup their investments and generate long-term returns.

Q: How high pressure gas-liquid pump work?
ꄶ ꄶ ꄷ

A: By the upper and lower ends of the piston area is poor, and get the high pressure fluid output, piston-driven gas side is a low pressure area, another liquid piston due to its small size, and high pressure. 

Q: How much is the maximum rated pressure of the pump?
ꄶ ꄶ ꄷ

A: Maximum output pressure is 67,860 PSI (4680bar). 

Q: Liquid pumps for oil or water?
ꄶ ꄶ ꄷ

A: Pump wetted parts material suitable for most liquids. Very minor changes to the pumps can be used solvents, deionized water and oil and skydrol.

Q: Hydraulic pump is suitable for valve, hose, pipe and hydraulic reservoir static pressure test?
ꄶ ꄶ ꄷ

A: Replace the manual pump, automatically and precisely, saving time and significantly superior.

Q: Is it safe to use Telide pumps in hazardous areas?
ꄶ ꄶ ꄷ

A: Unlike electric pumps, Telide pumps are air-driven and are free of electrical arcs and sparks, making them safe for use in hazardous areas and confined spaces.

Q: Typical applications of gas drive air pump?
ꄶ ꄶ ꄷ

A: Industrial applications include charging accumulators, pressure-filled tire, filled shock absorber bracket, gas from one cylinder to another storage container, or in the machine tool for pneumatic clamps, for industrial machinery or test equipment of high-pressure gas in place. Gas drive air pump or air pump to provide special forces. Gas drive air pump output 10,000psi (690bar) high pressure gas. 

Q: Is it safe to use Telide products?
ꄶ ꄶ ꄷ

A: Product design and safety factor of not less than 2:1. 

Q: What are the advantages of HiP products?
ꄶ ꄶ ꄷ

A: A full range of high pressure VFT products. Pressure up to 1000MPa, size up to 1-1/2”, stable performance, moderate price.

Q: What is the maximum output pressure of a Scanwill intensifiers?
ꄶ ꄶ ꄷ

A: Maximum output pressure is 4,000bar.

Q: What are the advantages of using this type of intensifiers?
ꄶ ꄶ ꄷ

A: There is no need for high pressure valves, relief valves, etc., controlling high pressure with low pressure.

Q: Is the intensifier continuously automatic?
ꄶ ꄶ ꄷ

A: Yes, using low pressure hydraulic drive of the system itself. 

After-sales service

Tel:+0086 755 3361 1128
E-mail:sales@telide.com.cn

Assist to install and adjust the equipment through the internet for you.
Provide technical training instructions till you can operate skillfully.
One year warranty for the complete equipments.

 

Maintenance: We can exchange parts and provide service for free during the guarantee period timely and effectively when there are problems .Once get the problems, our engineers will make a solution to help resolve them in the shortest time.

Technical Article

Elevated Temperature Usage

 

The following graph is for use with the Nova range of 316 stainless steel fittings and tubing. The thick line depicts the reduction in yield stress of the 316 and the corresponding reduction in valve rated pressure (some items may be used in the area above the line – consult agent or factory for specific cases).

 

The graph should be used for reference only as other considerations such as fatigue, creep, corrosion etc can affect performance at elevated temperatures. Please consult agent or factory for unusual operating conditions.

 

 

 

Standard Materials of Construction

 

Fittings (10,20,30,000 psi) AISI 316 L/DIN 1.4404 to NACE MR-01-75
Fittings (60,000 psi/4000 bar/100,000 psi/7000 bar) AISI 316 L/DIN 1.4404
Tubing (20, 30,000 psi) AISI 316 L/DIN 1.4404 to NACE MR-01-75
Tubing (10, 20, 60,000 psi/4000 bar/100,000 psi/7000 bar) AISI 316 L/DIN 1.4404
Filters (4000 bar) AISI 316 L/DIN 1.4404

 

 


SPAREs KITS


To order spares kits, insert SK- in front of the valve catalogue number (see examples below).
To order individual connection components, use the catalogue numbers in the Fittings section.
To order any other individual components, contact factory or local agent.

 

 

 

LIQUID FLOW COEFFICIENTS KV IN M3/H


Kv values according to DIN EN 60543-2-3 for flow of water.
kv: flow of water in m3/h, temperature 5 to 30°C at a pressure drop of 1 bar (14.5 psi), in a determined direction through an object. Instruments in fully open position.

 

 

 

FLOW THROUGH CHECK VALVES AT VARIOUS PRESSURE

 

Note: Due to our policy of continuos development we reserve the right to modify products and specifications without notice.

Download

HiP high pressure valves, fittings & tubing

끂 Download

Swiss Nozag NSE Configurator

끂 Download

NOVA Swiss high pressure valves, fittings & tubing

끂 Download

Swiss NOZAG screw jacks and systems

끂 Download

Video

BC-03 DIGITAL BUBBLE COUNTER

To view this video please enable JavaScript, and consider upgrading to a web browser that

视频播放失败,请联系站点管理员!

BC-03 DIGITAL BUBBLE COUNTER

To view this video please enable JavaScript, and consider upgrading to a web browser that

视频播放失败,请联系站点管理员!

BC-03 DIGITAL BUBBLE COUNTER

To view this video please enable JavaScript, and consider upgrading to a web browser that

视频播放失败,请联系站点管理员!

Agent Products

  • Sprague Products Air Driven Pump

  • American HiP High Pressure Components

  • Nova Swiss High Pressure Components

  • Denmark ScanWill Hydraulic Intensifiers

  • Swiss NOZAG Screw Jacks

TELIDE Products

  • Air Driven,Gas Booster Power Units

  • Valve Test Benches

  • Valve Grinders

  • Hydrostatic & Impulse Test Benches

  • Diaphragm Compressor HP System

  • Bolt Tensioner & Hydraulic Wrench Pumps

  • Computer Registration System

  • Non-standard Components Customization

Applications

  • General Industry

  • Auto Industry

  • Hydrogen

  • Oil & Gas

  • Nuclear Power

  • Research and University

  • Aviation Industry

  • Special Equipment Inspection

  • Cables

  • Petrochemical & Chemical

Contact Us

TEL: +86-755-3361 1191
E-mail: sales@telide.com.cn 
Website: www.telide.ru
Address: 4th Floor, Building 13A, Zhonghaixin Innovation Industry City, Ganli Sixth Road, Jihua Street, Longgang District, Shenzhen, 518112 China

Copyright © Telide Shenzhen High Pressure Fluid Systems Co., Ltd.
  • 끅
    • 客服电话

    • 88888888
  • 뀩
    • QQ客服
  • 뀥
    • 服务时间

    • 周一至周五 9:00-18:00
  • 낃
    • 微信二维码

  • 녕
 本网站由阿里云提供云计算及安全服务
本网站支持 IPv6
 本网站由阿里云提供云计算及安全服务
本网站支持 IPv6
 本网站由阿里云提供云计算及安全服务
本网站支持 IPv6
 本网站由阿里云提供云计算及安全服务
本网站支持 IPv6